Fireray ONE, 4 prisms

761417 | Fireray ONE, 4 prisms

As 761416, but with 4 prisms.

The self-aligning linear smoke detector Fireray ONE consists of the detector unit and 4 prism reflectors. Connection to the loop and resetting are carried out via the esserbus transponder (Part No. 808623.40).

The detector unit contains the infrared transmitter and receiver and operates at a range of 5 to 120 m when using the prism reflector.

Part-No.:
761417
Approval:
G 218070

Features

  • Reichweite 50 bis 120 m

Technical Data

Operating voltage 
14 ... 36 V DC
Feuerbeständigkeit 
Ankerlast 
Verankerungstiefe 
Min. Zugfestigkeit 
Specification 
Spezifikationen 
Zertifikate 
Kommunikationsprotokoll 
Kommunikationsschnittstellen 
Kontakteingänge 
Optische Anschlüsse 
Anzahl Alarmzonen pro Kanal 
Messzykluszeit 
Mindestmessintervall 
Anzahl Messkanäle 
Hochgeschwindigkeitsreaktionszeit 
Wärmeverhaltensklassen gemäß EN54-22 
Explosionserkennung 
Zulassung für explosionsgefährdete Bereiche 
Spektrale Empfindlichkeit 
Reaktionszeit_a 
Empfindlichkeitsbereiche 
Erfassungsbereich 
Contact Ausgänge 
Contact Current 
Sensoren pro Hub 
Sensoren pro Controller 
Hubs pro Controller 
Angesaugte Lufttemperatur 
Länge der Abzweigleitung 
Lineare Rohrlänge 
Ansaugöffnungen 
Operation temperature 
Anzahl_der_Relaisausgänge 
Indication Output voltage 
Nominal frequency 
Hz
Rated voltage 
 
Operating voltage 
V DC
Operating voltage 
Voltage supply 
Quiescent current 
Quiescent current @ 9 V DC 
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
Quiescent current @ 24 V DC 
Ruhestrom @ 28 V DC_comp 
Quiescent current @ FACP battery 
Quiescent current @ FACP battery 
 
Current consumption 
Alarmstrom @ 28 V DC_comp 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Current consumption 
Power consumption @ 5 V DC 
Power consumption @ 12 V DC 
Power consumption @ 24 V DC 
Alarm current @ 9 V DC 
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
Starting current @ 24 V DC 
Starting current 
Current consumption in the case of failure 
Output current 
A
Power consumption 
Current consumption for ext. devices 
A
Battery capacity 
Contact load 
Contact load relay 
Sensitivity 
Sound level 
Sound level @ 24 V DC 
Display 
Frequency of flash 
Hz
Lighting energy 
Range 
50 … 120 m
Connection terminal 
Maximum tube length 
Area to be monitored 
Height to be monitored 
Alignment angle 
Unempfindlichkeit gegenüber Gebäudebewegungen 
Air velocity 
Application temperature 
Response temperature 
Ambient temperature 
-20 °C ... 55 °C
Storage temperature 
-40 °C ... 80 °C
Wavelength 
nm
Connection 
Sampled Air Temperature 
Air humidity 
Air humidity 
Ex-category 
Ex. protection 
Type of protection 
IP 55
 
Housing 
Type 
Material 
 
Color 
Weight 
Weight 
approx. 0,7 kg (detector), approx. 0.1 kg (4 prisms)
 
Luftfeuchtigkeit 
< 93 %
Cable length 
m
Maximum sensor length 
m
Einstellbare minimale räumliche Auflösung 
Rückseitige Bodenplatte 
mm
Detector specification 
EN54-12
EC-type examination certificate 
Specification 
 
Dimensions 
W: 200 mm H: 200 mm D: 9 mm (4 prisms)
 
 
Declaration of Performance 
Approval 
Systemausgänge 
Eingangsspannungsbereich 
Maximale Anzahl von Sensoren pro Modul 
Stromverbrauch 
Ausgang 
Temperature range 
Max. Temperaturänderung 
Relaislast 

Accessories

761419 Fireray ONE, protective cage

761420 Fireray ONE, heating

Additional information

The device requires a separate power supply.

Scope of delivery

1x signaling unit

4 x prisms

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2025-07

Language:
English
Doc extension:
pdf