OTblue-LKM multisensor detector IQ8Quad with isolator

802379 | OTblue-LKM multisensor detector IQ8Quad with isolator

Specially addressable IQ8Quad multisensor fire detector with integrated optical sensor and heat sensor and enhanced false alarm management. For application as air duct smoke detector in venturi air duct modules Part Nos. 781443 and 781463. The optical measurement chamber is provided with a patented developed sensor technology using a high-sensitive blue LED (instead of the commonly used red LED in Optical smoke detectors), enabling the detection of open fires, smoldering fires and fires with high heat generation.

Especially for open fires, the classical ionization technology implemented in ionization detectors is replaced by the unique detection technology, unlike ionization detectors, this sensor works without a radioactive element which causes problems at the time of refuse disposal. The detector is capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 specification. Well suited for sensitive environment, detection of invisible up to large aerosols.

The OTblue multisensor is an intelligent detector with time-related signal analysis, signal correlation of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, automatic adaptation to environmental conditions, alarm and operating data memory, alarm indicator and soft-addressing.

The detector is provided with an integrated isolator and a parallel detector indicator can be connected.

Part-No.:
802379
Approval:
VdS

Technical Data

Operating voltage 
9 ... 42 V DC
Contact Ausgänge 
Contact Current 
Sensoren pro Hub 
Sensoren pro Controller 
Hubs pro Controller 
Angesaugte Lufttemperatur 
Länge der Abzweigleitung 
Lineare Rohrlänge 
Ansaugöffnungen 
Operation temperature 
Anzahl_der_Relaisausgänge 
Indication Output voltage 
Nominal frequency 
Hz
Rated voltage 
 
Operating voltage 
V DC
Operating voltage 
Voltage supply 
Quiescent current 
Quiescent current @ 9 V DC 
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
approx. 50 μA
Quiescent current @ 24 V DC 
Ruhestrom @ 28 V DC_comp 
Quiescent current @ FACP battery 
approx. 200 μA @ 27,5 V
Quiescent current @ FACP battery 
approx. 280 μA @ 42 V
 
Current consumption 
Alarmstrom @ 28 V DC_comp 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Current consumption 
Power consumption @ 5 V DC 
Power consumption @ 12 V DC 
Power consumption @ 24 V DC 
Alarm current @ 9 V DC 
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
Starting current @ 24 V DC 
Starting current 
Current consumption in the case of failure 
Output current 
A
Power consumption 
Current consumption for ext. devices 
A
Battery capacity 
Contact load 
Contact load relay 
Sensitivity 
Sound level 
Sound level @ 24 V DC 
Display 
Frequency of flash 
Hz
Lighting energy 
Range 
Connection terminal 
Maximum tube length 
Area to be monitored 
Height to be monitored 
Alignment angle 
Unempfindlichkeit gegenüber Gebäudebewegungen 
Air velocity 
1 m/s ... 20 m/s
Application temperature 
-20 °C ... 50 °C
Response temperature 
Ambient temperature 
Storage temperature 
-25 °C ... 75 °C
Wavelength 
nm
Connection 
Sampled Air Temperature 
Air humidity 
< 95 % (non condensing)
Air humidity 
Ex-category 
Ex. protection 
Type of protection 
IP 43 (with base + option)
 
Housing 
ABS plastic, white, similar RAL 9010
Type 
Material 
 
Color 
Weight 
approx. 110 g
Weight 
 
Luftfeuchtigkeit 
Cable length 
m
Maximum sensor length 
m
Rückseitige Bodenplatte 
mm
Detector specification 
EN 54-17:2005, CEA 4021
EC-type examination certificate 
Specification 
 
Dimensions 
Ø: 117 mm H: 62 mm (incl. base)
 
 
Declaration of Performance 
DoP-20116130701
Approval 

Accessories

805590 Standard detector base for IQ8Quad

805591 Detector base with relay contact for IQ8Quad

Additional information

Only suitable for application in air duct construction set 781443.

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2024-06

Language:
English
Doc extension:
pdf