Multi-stimulus detector tester TF 2001

805551 | Multi-stimulus detector tester TF 2001

Detector tester kit Testifire 2001 for the functional testing of point-type fire detectors with various sensors. The activating stimuli for smoke, heat and CO (carbon monoxide) are generated in this testing unit. Thus the changing of test tools for different types of detectors is no longer necessary.

All fire detector types can be tested with only one test instrument. The test tool is suitable for all optical smoke detectors, ionization detectors, CO detectors and heat detectors. It facilitates fast and effective testing of single and intelligent multisensor fire detectors. So testing of the different sensors can be carried out one after another or for all at the same time.

The required stimuli are generated on demand at the time of test from the corresponding capsule (smoke or CO). Pressurized gas cans are no longer being used.

The selection of the testing stimuli, as well as their combination and sequence are menu driven via keypad and are represented on the display (multilingual). So e.g. simultaneous or sequential testing, or also a combination thereof, can be easily programmed and then carried out at the detector. The activation of the testing device occurs automatically, as soon as the detector interrupts the light barrier integrated in the device. If necessary, a clearing phase can be chosen between the specific testing criteria that enables the stimuli to be blown out of the detector immediately for the next test by the integrated ventilator.

The currently active criterion is represented by a multi-colored LED indicator and is clearly recognizable even from large distances. The fill-level of the respective test resource capsules can be shown in the display. Warnings are indicated automatically e.g. if a capsule is nearly empty. The capsules offer much higher test capacities in comparison with aerosol cans.

The power supply of the testing head occurs via Ni-MH batteries (metal hydride batteries) in the adapter between testing head and telescopic rod. Charging of the battery occurs with the charger optionally via adapter (100-230 V AC) or via 12 V DC input (vehicle cigarette lighter).

Suitable for IQ8Quad and 9x00 detector series.

Part-No.:
805551

Features

  • Generation of smoke, heat and CO in a single test unit
  • Clearing cycle of the detector via integrated ventilator for better reset
  • Simultaneous or sequential testing with various stimuli
  • Suitable for single and multi-criteria fire detectors
  • Suitable for smoke-, heat- and gas- (CO) detectors
  • Targeted heat rays provide fast activation of heat sensors (up to 90°C/194°F, and/or adjustable up to 100°C/212°F)
  • Test activation via infrared barrier, no mechanical triggering, no ceiling contact necessary
  • Easy, fast and efficient testing, as changing of testing device is not necessary
  • Multilingual and user-friendly menu control: English, German, Spanish, French, Italian, Dutch, Swedish
  • Battery operated portable device
  • Environmentally friendly and safe through usage of test cartridges instead of test gas cans

Technical Data

Common technical data: 
Leistungserklärung 
Rated voltage 
V AC
Rated frequency 
Rated current 
Output current 
Battery capacity 
Operating voltage 
 
Operating voltage 
V DC
Operating voltage 
Quiescent current 
Lichtquelle 
Leuchtfarbe 
 
Quiescent current @ 9 V DC 
μA
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
μA
Quiescent current @ 24 V DC 
Quiescent current @ FACP battery 
Quiescent current @ FACP battery 
Quiescent current 
μA
Current consumption 
Current consumption 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Starting current 
mA
Current consumption in the case of failure 
mA
Current consumption testmode 
mA
Alarm current 
Alarm current 
Alarm current @ 9 V DC 
mA
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
mA
Alarm current @ 24 V DC 
Alarm current w/o communication curtain 
mA
Power consumption 
Current consumption for ext. devices 
A
Testing capacity 
Battery charging 
75-90 minutes
Heat detector response threshold 
up to 90°C adjustable up to 100°C
Load factor 
Contact load relay 
Contact load 
Sound level 
dB
Sound level @ 12 V DC 
Sound level @ 24 V DC 
Sound level 
No. of detector/zone 
Circuit 
Display 
Operation indicator 
Alarm display 
Fault display 
Frequency of flash 
Lighting energy 
Flash color 
Luminous intensity 
 
 
Signal flashing lamp 
Range 
Connection terminal 
CO pre-alarm 
ppm
CO alarm 
ppm
Area to be monitored 
Height to be monitored 
Air velocity 
Sensitivity 
Application temperature 
Ambient temperature 
5 °C ... 45 °C
Storage temperature 
-10 °C ... 50 °C
Air humidity 
< 85 %
Air humidity 
Type of protection 
 
Protection class 
Ex. protection 
Category 
Housing 
Material 
 
Installation 
Signal Range 
Mounting height wall 
Room width 
Category ceiling 
Mounting height ceiling 
Room diameter 
Color 
 
Weight 
Weight 
Optisches_Signalbild 
Lebensdauer_optisch 
Drehfrequenz 
Abmessungen 
Content 
Cable length 
m
Maximum sensor length 
m
Detector specification 
DIBt approval 
Specification 
 
Cable diameter 
mm
Cable entry 
Maximum tube length 
Dimensions 
 
Length 
Declaration of Performance 
Konformität 

Accessories

805552 Smoke capsule for multi-stimulus detector tester 805550/51

805553 CO capsule for multi-stimulus detector tester 805551 (Testifire TC3)

060426 Plastic telescopic extension

060427 Plastic telescopic rod

060431.10 Spare battery baton

805543.10 Solo Universal Fast Battery Charger SOLO 727

Additional information

Please consider the safety instructions for this device.

Scope of delivery

Detector tester kit Testifire 2001 consists of:

Testing head, smoke capsule, CO capsule, 2 Ni-MH battery packs, charger

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2024-05

Language:
English
Doc extension:
pdf