IQ8Wireless universal interface w/o cover, white

IQ8Wireless universal interface w/o cover, white

Part No.:
805602.10 
Approval:
VdS 

Description

The radio interface allows the IQ8MCP (small or large design) to be connected on the wireless esserbus-PLus.

The radio interface connects the intelligent IQ8MCP to the esserbus/powered loop via the IQ8Wireless transponder or the IQ8Wireless gateway. Thus, the devices are automatically converted into individually addressable loop devices.

Features

Radio interface suitable for:

IQ8MCP - electronic module, large design (Part No. 804905/ 804906)

IQ8MCP – complete package, small design (Part No. 804971)

IQ8MCP - electronic module, small design (Part No. 804955), only with mounting frame (Part No. 704967)

IQ8Quad detectors (with and without alarm signaling devices)

IQ8Alarm alarm signaling device (Part No. 8073xx)

Radio interface features:

The IQ8 components are individually identified on the FACP

Regular functionality performance checks of IQ8 components

Fault signal when the IQ8 components are removed from the FACP

Operating mode display directly at the IQ8 manual call point and IQ8Quad detector

Alarm and fault message transmission in compliance with EN 54-2

Easy detector removal and battery replacement using multi-functional key

Remote operation of IQ8 components possible (max. 3 meters) via 2-wire line

Constant battery status monitoring

Early battery replacement notification at the FACP

Technical Data

Rated voltage 
Rated voltage 
V AC
Rated voltage 
V DC
Rated voltage 
V
Rated frequency 
Rated current 
Operating voltage 
V DC
Operating voltage 
Battery 
 
 
 
max. A
max. cont. operating voltage a.c. 
V AC
max. cont. operating voltage d.c. 
V DC
Nom. discharge current (80/20)/line 
A
Total nom. discharge current 
kA
Lightning imp. current (10/350)/line 
kA
Total lightning imp. current (10/350) 
kA
Combined impulse [L+N-PE] 
kV
Combined impulse 
kV
Voltage protection level [L/N-PE] 
≤ V
Voltage protection level [L-N] 
≤ V
Response time [L-N] 
≤ ns
Response time [L/N-PE] 
≤ ns
Operating voltage 
4 x 3.6 V batteries
 
Operating voltage range #4 
Output voltage 
Output voltage 
Power consumption 
Power consumption 
W
Current consumption 
< mA
 
Current consumption 
approx. 30 μA
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Current consumption testmode 
approx. mA
Current consumption in the case of failure 
max. mA
Quiescent current 
Quiescent current @ 12 V DC 
Quiescent current @ 9 V DC 
approx. μA
Quiescent current @ 24 V DC 
Quiescent current @ 19 V DC 
approx. μA
 
Quiescent current @ FACP battery 
Alarm current @ 12 V DC 
Alarm current @ 9 V DC 
typ. mA
Alarm current @ 24 V DC 
approx. mA
Alarm current 
Alarm current w/o communication curtain 
approx. mA
Current consumption for ext. devices 
A
Current consumption active 
max. mA
Battery capacity 
Battery charging 
Output current 
Output current 
Emergency power supply 
Contact load 
Contact load relay 
Interface 
Display 
Alarm display 
Battery life expectancy 
Battery operating time 
approx. 3 years*
Battery charging time 
Battery charging 
Inputs 
Outputs 
Power supply 
 
Operation indicator 
Sound level 
Sound level 
Frequency range 
Frequency band 1 
433 MHz with 16 channels
Frequency band 2 
868 MHz with 7 channels
Data transmission speed 
19,2 Kbit/s
Sensitivity 
dBm
Signal flashing lamp 
Luminous intensity 
Frequency of flash 
approx. Hz
Lighting energy 
Area to be monitored 
Height to be monitored 
 
Range 
Range inside 
max. 30 m
Range outside 
max. 300 m
Sound level @ 24 V DC 
Air speed 
Air speed 
No. of detector/zone 
Ambient temperature 
 
Ambient temperature (Ta) 
Response temperature 
Heat detector response threshold 
Application temperature 
-5 °C ... 55 °C
Operating temperature range #2 
Storage temperature 
-20 °C ... 70 °C (w/o batteries)
 
15 °C ... 35 °C (with batteries)
Storage temperature #3 
Storage temperature range 
Max. Output current (Io
mA
Max. Input Voltage (Ui
V DC
Max. Input current (Ii
mA
Max. internal capacity (Ci) 
Explosion protection 
Category 
Cable 
Cable length 
Connection terminal 
Loading capacity 
W
Transformer power taps 
Audio input 
Communication Station connections 
Power output 
Backup / Reserve amplifier 
Call circuits 
Testing capacity 
Type of protection 
IP 42
 
Class of protection 
Housing 
Material 
PC/ASA plastic
 
Mounting 
 
Installation 
Version 
Air humidity 
Air humidity 
< 95 %
Color 
white, similar to RAL 9010
 
 
Weight 
approx. 285 g (incl. batteries, without attachment)
Weight 
 
Detector specification 
EC-type examination certificate 
Specification 
EN 54-18:2005/-25:2008
Maximum tube length 
Length 
Dimensions 
W: 135 mm H: 135 mm D: 20 mm (without attachment)

Accessories

704967 Mounting frame for small MCP

805603 IQ8Wireless-mounting frames for IQ8Alarm

805604 IQ8Wireless-mounting frames for IQ8Quad

Additional information

Only use small manual call points with mounting frame Part No. 704967.

The batteries to be used are components of the device approval according to EN 54 and are specified by the manufacturer. With the IQ8Wireless radio components, only the approved batteries with Part No. 805597 may be used. Use of batteries other than those specified by us automatically voids the product’s device approval (VdS-approval) and may not be used for example in Germany in fire alarm systems under legal building regulations.

*The battery operating time is dependent on the type of detector/device used, as well as the application temperature and additional surrounding conditions. It can be substantially restricted by increased current consumption of the wireless devices in the case of alarm, wireless interference or poor transmission, or even possibly through contact resistance at the contacts. Please note important instructions for usage of batteries in in manual Part No. 798941.10 (available at the website).

Scope of delivery

4 x 3.6 V lithium batteries (Part No. 805597)

Delivery time

Downloads

  • Product data sheet - IQ8Wireless - universal interface

    Version: 07.2011, Language: English
    Part No.: , File Size: 487 kB, Doc extension: pdf

    Download
  • Brochure, IQ8Wireless

    Version: 07.2011, Language: English
    Part No.: , File Size: 1324 kB, Doc extension: pdf

    Download